Help & Reference
Howler
A sound level meter for Android. Real-time SPL in decibels — A, C, and Z weighting, Fast and Slow time response, Max / Min / Leq, and single-point calibration.
Calibration
Readings vary by device. Android microphones are tuned for voice calls, not measurement — two phones in the same room can read 10–15 dB apart. Without calibration, Howler's readings reflect relative changes accurately but absolute values may be off by that margin. If you need a number to trust, calibrate first.
With calibration, Howler targets approximately ±2 dB(A) — enough to make real decisions about whether a room, a stage, or a machine is actually loud.
How to calibrate
- 01 You need a reference source — a calibrated SPL meter, a sound level meter app on a second phone that you trust, or a known test signal at a known level.
- 02 Place both devices at the same location and point them at the same sound source. Use a steady, continuous sound — a tone, a fan, or any consistent ambient source. Avoid handholding both at once; your body will affect the reading.
- 03 Tap the accuracy label at the bottom of the Howler screen to open the calibration dialog. Enter the reference reading. Howler stores the offset and applies it from that point on.
- 04 The calibration persists across restarts. To clear it or re-calibrate, open the dialog again and tap Clear.
Note
Howler is not a certified Type 1 or Type 2 sound level meter and should not be used for legal, regulatory, or occupational-compliance measurements. For OSHA or NIOSH compliance work, use a certified instrument.
Frequency weighting — A · C · Z
Not all frequencies are equal — human hearing is most sensitive around 1–4 kHz and rolls off toward bass and treble. Frequency weighting shapes the measurement to account for this.
A-weighting — dB(A)
Follows the sensitivity curve of human hearing. Bass frequencies are de-emphasized; the 1–4 kHz range that the ear is most sensitive to carries the most weight. Use A for anything related to hearing damage, comfort, or noise ordinances — it correlates best with how loud something actually sounds and feels over time. Most regulatory limits (OSHA, NIOSH) are specified in dB(A).
C-weighting — dB(C)
A flatter curve that still rolls off at the extremes but passes more bass than A. Use C for peak measurements or when low-frequency content matters — bass-heavy music, machinery with a lot of low-end energy, HVAC. C captures the physical punch that A ignores.
Z-weighting — dB(Z)
Flat — no weighting applied. The raw, unfiltered signal level from 20 Hz to 20 kHz with equal weight at every frequency. Use Z when you want to know the true acoustic energy regardless of how it sounds to a human ear, or when comparing against an unweighted specification.
Time response — Fast · Slow
SPL meters average sound over time — a single instantaneous sample is too noisy to read. The time response sets how quickly the displayed level tracks changes in the sound.
Fast — 125 ms
The display updates quickly and follows transients closely. Use Fast when you need to catch short events — a snare hit, a door slam, a brief spike — or when you want to see how dynamic a source is.
Slow — 1 s
The display moves more smoothly and reflects a longer average. Use Slow when you want a stable, readable level for a sustained sound — a room's ambient noise, a crowd, a running machine. Less reactive to momentary spikes.
Switching between Fast and Slow resets Max, Min, and Leq, since the units are no longer comparable.
Measurement modes — Max · Min · Leq
Tap the mode label to switch between Max, Min, and Leq. Tap Reset to clear all three and start a fresh accumulation from the current moment.
Max — peak hold
The highest level recorded since the last reset. Useful for catching peaks in a variable environment without having to watch the screen continuously. Persists across the screen turning off and back on.
If Max carries a ≥ symbol, at least one clipped block was included in the peak — the true maximum was at or above the displayed value.
Min — minimum hold
The quietest level recorded since the last reset. Useful for characterizing the noise floor of a space — the baseline when the room is as quiet as it gets.
Leq — equivalent continuous level
The energy-averaged level over the entire measurement period — the single number that represents the total sound exposure since the last reset, regardless of how the level varied over time. Leq is independent of Fast / Slow; it accumulates raw energy.
Leq is the quantity used in noise exposure standards. A Leq(8h) of 85 dB(A) is the typical 8-hour threshold at which hearing protection is recommended.
OVER indicator
The OVER indicator lights when the microphone signal has clipped — the input exceeded what the mic and ADC can faithfully represent. When OVER is lit, the displayed level is a lower bound on the actual sound level; the true level was at least that high, and possibly higher.
Clipping on a phone microphone typically happens above roughly 120–130 dB SPL — louder than most everyday environments. If OVER lights consistently, you are in a very loud space or the mic is being obstructed.
Privacy
Howler processes audio entirely on your device. Nothing is recorded, stored remotely, or transmitted. No accounts, no analytics, no ads. See the full privacy policy.